ST-3 Noise Attenuation trim works to reduce control valve noise in a broad spectrum of gas applications. ST-3 trim has two variants: the first is a one or two-stage design that reduces noise levels up to 15 dBA, the second is a multi-stage design for more extreme noise reduction up to 30 dBA. ST-3 works by controlling both pressure and velocity of the gas through the valve, thereby reducing turbulence, which is the culprit of all aerodynamic control valve noise. Multi-stage ST-3 reduces pressure with a concentric cylinder design similar to the ST-2 anti cavitation trim.

Technical Specifications

Type: ST-3 Noise Attenuation Trim
Base Valve: Optimux OpGL Globe or Angle Body
Size Range: 1” to 32”
CV Range: 1 to 3220
Flow Direction: Flow Under
Pressure Stages: 1 to 6
Features: • Effective attenuation of up to 30 dBA of noise
• 1 or 2 stage cartridges fit a standard OpGL without modification